Heater opoeration procedure, Series two heater 10 - 15 hp units – Grain Systems PNEG-584 User Manual

Page 15

Advertising
background image

15

SERIES TWO HEATER

10 - 15 HP UNITS

HIGH TEMPERATURE 10-15hp 7/32" orifice

OPERATING PRESSURE (PSI)

2

4

6

8

10

12

14

15

ALL
MODELS

816013

1148640

1409477

1632026

1825859

1995762

2153700

2227883

Static

Fan Model

Pressure

60

80

100

120

140

160

180

2"

2

4

6

8

10

13

10HP

4"

1

3

5

6

8

11

14

6"

1

1

3

5

6

8

10

2"

3

6

9

12

15

15HP

4"

3

5

7

10

13

6"

2

3

5

6

9

11

14

Gauge Pressure (Psi) Required To Maintain Temperature ( Approximate )

( 10-15 Horsepower High Temp Propane Units Only )

Heat Rise Degrees F

Static

Fan Model

Pressure

60

80

100

120

140

160

180

2"

1

1.75

2.5

3.5

4.75

6

10HP

4"

0.75

1.25

2

2.75

3.75

4.75

6

6"

0.5

1

1.5

2

2.75

3.5

4.25

2"

1.5

2.5

3.75

5.5

15HP

4"

1.25

2

3

4.25

5.75

6"

0.75

1.25

2

2.75

3.75

5

6

( 10-15 Horsepower High Temp Natural Gas Units Only )

Heat Rise Degrees F

Gauge Pressure (Psi) Required To Maintain Temperature ( Approximate )

BTU’s Per Gauge Pressure (PSI)

PROPOANE MODELS

(Approximate)

BTU’s Per Gauge Pressure (PSI)

NATURAL GAS MODELS

(Approximate)

1

2

3

4

5

6

7

ALL
MODELS

859104

1218432

1489296

1718208

1921584

2107632

2276352

HIGH TEMPERATURE 10-15hp 11/32” orifice

OPERATING PRESSURE (PSI)

HEATER OPOERATION PROCEDURE

Advertising