Heater installation, Series two heater, Wiring – Grain Systems PNEG-584 User Manual

Page 9

Advertising
background image

9

SERIES TWO HEATER

1. Be sure fan unit is installed and wired to meet local

codes. Be sure equipment is well grounded (see page 9).

2. A separate neutral is required for 120 volt heater

circuit in 220 volt 1PH and 3PH fan units. For 460 volt

fan units a separate 120 volt power supply or transformer

is required.

3. Run S-wire black cord from heater unit to fan unit

and secure to fan.

4. Orange and red wires should be connected in series

with coil in fan. When contacts in heater between these

wires open fan shuts down. Recommended wiring is

shown in Figure 2.

WIRING

HEATER UNIT

4. Third heater unit may also be added to system. If

adding third unit, run connections to master unit #1 and

connect them in parallel with secondary heater unit.

2. Run (2) 20 gauge (minimum) wires from secondary

heater unit (slave) to heater unit #1 (master).

1. Secondary heater unit runs as a slave of heater unit

#1 and re-quires no plenum or grain temperature sensor.

Figure 3: Secondary heater wiring diagram.

Figure 2: Wiring diagram for the fan and heater unit.

SECONDARY

HEATER UNIT

5. Black and white wires should be connected to a fused

120V power supply as shown. Green wire should be con-

nected to ground in fan.

HEATER INSTALLATION

3.

Connect wires as shown in Figure 3.

Advertising