SERIES TWO HEATER
CONFIGURATION DIP
SWITCHES (NORMALLY
DONE AT FACTORY)
Stand alone heater
with no slaves, all
dip switches in the
off state.
These switches are used to config-
ure the heater control for various
types of heaters.
Multiple heaters connected together through the serial link.
Master with one
slave-dip switch 7
on/all others off.
Slave #1-dip switch
one on/all others
off.
Master with two
slaves-dip switch 8
on/all others off.
Slave #2-dip switch
two on/all others
off.
Master with 3
slaves-dip switch 7
& 8 on/all others
off.
Slave #3-dip switch
one & two on/all
others off.
The backside of the control board, showing the dip switch placement.
FACTORY CONFIGURATION