SERIES TWO HEATER

PLENUM TEMPERATURE

SENSOR MOUNTING

The plenum temperature sensor is

the white PVC junction box with bolt

extending from outside attached by

a cord to the fan/heater control box.

1. 24" to the right side of the transi-

tion, drill one 3/8" hole in the cen-

ter of the plenum in a valley on

the bin sidewall.

2. Insert the probe through the hole.

3. Position the housing so that the

tabs are vertical, and the cord

exits the housing horizontally.

4. Use two self drilling screws to mount

the housing to the bin sidewall.

5. Caulk between the housing and

the sidewall to seal.

Plenum temperature sensor installation.

1. Mark location on transition one

(1) foot up from the bottom

(entrance collar) and centered

in the transition.

2. Drill or knock out 7/8" diameter

hole on marked location.

3. Install transition hi-limit using

supplied self drilling screws.

TRANSITION HI-LIMIT INSTALLATION

Figure 1: The transition connecting the heater to the bin with the plenum

thermostat in place.