Heater opoeration procedure, Series two heater – Grain Systems PNEG-584 User Manual

Page 20

Advertising
background image

20

SERIES TWO HEATER

On hi-lo units when the unit reaches cycle set point,

the flame will switch to lo-flame and unit will not cycle

back to hi-flame until (Set Point minus Temperature Dif-

ferential) is reached.

Temperature differential would normally be set for

10-15 degrees F for high temp units, and 2-5 degrees F

for lo-temp units.

Humidity Differential--The upper right cursor is

flashing indicating the mode. If the flame shuts off

because

MULTIPLE HEATER NOTES

When multiple heaters are connected

together, the temperature and humid-

ity sensors must be connected to the

master.

the switch, depress the up and down arrow switches to

alter the hours. Setting range is 0 to 200 hours.

DRYING GRAIN IN THE HOURS TO SHUT

DOWN MODE

While drying grain, depress and hold the "SHUTDOWN

HOURS" switch. While holding in on that switch, de-

press the "START" switch. After depressing the start

switch one time, the heater is in the shutdown mode. Then,

RUN HOURS DISPLAY

Run hours are recorded when the

controller detects that the fan is on

(airflow). The hours may be viewed

by depressing the "HOURS" to get

hours and "HOURS X 1000" to get

the number of 1000 hours accumu-

lated.

the humidity is less than the humidity set point,

the humidity must rise above the (Set Point plus Humid-

ity Differential) for the flame to come back on.

PROGRAMMING HOURS TO SHUT DOWN

To change the hours to shut down, depress and hold the

"SHUTDOWN HOURS" switch. While holding in on

Setting the cycle set point.

HEATER OPOERATION PROCEDURE

the fan and heater shut down when

the time expires. This is indicated by

the lower left cursor flashing.

Depressing the start switch again

(while holding in on the "SHUT-

DOWN HOURS" switch) will cause

only the heater to shut off. This leaves

the fan on when the time expires. This

is indicated by the 2nd from lower left

cursor flashing. Depressing the start

switch one more time returns the

heater into the continuous--non-shut-

down mode.

Advertising