SERIES TWO HEATER

PROGRAMMING SET POINTS

multiple heaters may be done at any

heater control console. The infor-

mation programmed is automatically

transmitted to all other heaters when

the programming is complete.

Hi Limit Set Point--The upper

left cursor is flashing indicating the

mode. If the plenum temperature

increases above this point, the flame

is shut off--"OFF-CYCLE" is dis-

played on screen.

Cycle Set Point--The upper 2nd

from left cursor is flashing indicat-

Depressing the "PROGRAM" switch (lower left) causes

the display to enter the program mode. Each item below

is programmed by using the up and down arrow switches.

Holding down these up and down arrow switches for

about 2 seconds will cause the numbers to increase/de-

crease rapidly until the switch is released. When fin-

ished programming an item, depressing the "PROGRAM"

switch again will cause the new setting to be entered into

memory, and the display will advance to the next func-

The limits are continuously checked during the dry-

ing operation. A limit switch open or any other error

condition will cause the dryer to shut down, and the fan

will be shutdown. If a limit opens, or an error condi-

tion occurs during drying, the control will lockup in

the error display mode. Power must be shut off and

back on to the control to clear the error condition--

even if the error or limit that caused the shutdown

has been corrected. This is to keep the display locked up

with the condition that caused the error, allowing the opera-

tor time to determine what caused the shutdown.

above this point the dryer operates normally--flame on

and off at the high limit and cycle set points. If the hu-

midity is below this point the dryer goes into the "OFF-

CYCLE" mode. Note: At this time a true humidity

sensor has not been introduced. To use this option,

set the humidity setting to 50% and use a humidistat

switch. When the humidity is high the switch is closed,

indicating high humidity. At this setting, the dryer runs

normally.

Temperature Differential--The upper right cursor is

flashing indicating the mode. If the flame shuts off because

the temperature is greater than the high limit set point, the

temperature must fall below the (Set Point minus Tempera-

ture Differential) for the flame to come back on.

Programming the high-limit set point.

HEATER OPOERATION PROCEDURE

tion to be programmed.

Programming may be done at

anytime (unless an error condi-

tion exists) even while the dryer

is in operation.

Programming a system with

ing the mode. If the dryer is not a hi-lo dryer, this

function is skipped. If the plenum temperature increases

above this point, the flame reduces to "LO-FLAME".

Humidity Set Point--The upper 2nd from right cur-

sor is flashing indicating the mode. If the humidity is

Advertising