FLOAT SWITCH OPERATION - Filling a Pond or Tank

and Constant Pressure System:

• Connect two wires from a float (level) switch to fill or

empty a tank or pond and a pressurized system. The

maximum switch wire length tested is 200’. The pump

will operate at various speeds and try to maintain the set

point pressure. If piping is large and it cannot maintain

set point pressure it will operate at maximum speed.

• Typical UIB Settings:

• 60 or 80 Hertz (depends on pump/motor)
• Pump Stop – High
• Dry Well - High (switch to low if it trips while pumping)
• Low Pressure Cut-Off - On (switch to off if pressure

drops by 20 PSI or more)

• Pressure Drop - 5 PSI
• Transducer - Connected
• Transducer Jumper - Bottom Position (Factory Setting)
• Float Switch Connected to Switch Input

Transducer Jumper

Explosion Hazard. Keep jumper in bottom

position whenever a pressure transducer is

used. Failure to do so may cause a pressure transducer error

to be ignored and an over-pressure hazard to result.
For applications not requiring a pressure transducer such

as level control, the transducer can be removed. When

the transducer is not used, the Transducer Jumper must be

placed in the top position to prevent a sensor error. Never

place the jumper in the top position when using a pressure

transducer.

5: INSULATION AND WINDING

RESISTANCE TESTS

INSULATION RESISTANCE

Electrocution Hazard. Turn off power and

wait 5 minutes before opening cover.

1. Set the scale lever to R x 100K and adjust to 0.
2. Disconnect motor leads from controller (note position

of wires). Connect an ohmmeter lead to any one of the

motor leads and the other to the metal drop pipe. If the

drop pipe is plastic, connect the ohmmeter lead to the

metal well casing or ground wire.

Normal Ohm and Megohm Values (Insulation

Resistance) Between All Leads and Ground

Insulation resistance does not vary with rating. All motors of all
HP, voltage and phase rating have similar values of insulation

resistance.

Condition of Motor and Leads

Ohms

Megohm

Value Value

A new motor (without drop cable).

20,000,000

20.0

(or more)

A used motor which can be

10,000,000

10.0

reinstalled in the well.

(or more)

New motor in the well

2,000,000

2.0

(or more)

(or more)

Motor in the well in good condition

500,000 –

2,000,000

0.5 – 2.0

Insulation damage, locate and repair

Less than

Less than

500,000 .50

DANGER

DANGER

DANGER

What it Means

1. If the ohm value is normal, the motor windings are not grounded

and the cable insulation is not damaged.

2. If the ohm value is below normal, either the windings are grounded or

the cable insulation is damaged. Check the cable at the well seal as the

insulation is sometimes damaged by being pinched.

MOTOR WINDING RESISTANCE CHECKOUT
1. Set the scale lever to R x 1 for values under 10 ohms. For values

over 10 ohms, set the scale lever to R x 10. Zero balance the

ohmmeter.

Electrocution Hazard. Turn off power and

wait 5 minutes before opening cover.

2. Connect the ohmmeter leads as shown below.
Cable Resistance – Copper

See motor data pages for motor resistance ratings.

What it Means

1. If all ohm values are normal, the motor windings are neither shorted

nor open, and the cable colors are correct.

2. If any one ohm value is less than normal, the motor is shorted.
3. If any one ohm value is greater than normal, the winding or the cable is

open or there is a poor cable joint or connection.

4. If some ohm values are greater than normal and some less and the

motor is single phase with red, black and yellow wires, then the leads
are mixed.

Z E R O

O H M S

R X 1 0 0
R X 1 0
R X 1

R X 1 0 0 0

R X 1 0 K

R X 1 0 0 K

O H M S

RX1

or

RX10

Motor

Leads

Ground

Wire

If aluminum cable is used the readings

will be higher. Divide the ohm readings

on this chart by 0.61 to determine the

actual resistance of aluminum cable.

Size

Paired Wire

Cable Resistance

(ohms per foot)

14

.0050

12

.0032

10

.0020

8 .0013

6 .0008

4 .0005

2 .0003

0 .0002

00

.00015

000

.00013

0000

.00010

5: INSULATION AND WINDING

RESISTANCE TESTS

OHMS

R x 1000

R x 10K

R x 100K

R x 100
R x 10
R x 1

ZERO

OHMS

R x 100K

Drop

Cable

with

Ground

Wire