USER INTERFACE BOARD

USER INTERFACE BOARD

Figure 3: UIB (User Interface Board)

1AS Controllers

3AS Controllers

Switch

Input

Switch

Input

Indicator

Transducer

Input

Transducer

Jumper

Drive

Settings

Pressure

Adjust

Controller

Status

Indicator

Motor

Controller Model

Circuit Generator

HP Voltage

1AS15 3AS20 3AS30 3AS50

Breaker

(VA)

½

230

2200

200

¾

230

15

2900

200

1

230

3500

200

230

20

4400

200

2

230

6100

200

30

230

3

200

8100

40

5

230

50

13300

200

Table 3: Controller, Breaker, Generator Sizing

Table 4: Service Factor Amps – All Motors

Supply voltage must be 196 VAC –

265 VAC.

Shaded areas indicate which controller

models can be used with which motors.

Lighter shading indicates combinations

where controller will limit peak performance

to 85% of catalog value for pump/motor.

Circuit Breaker or Dual Element Time Delay

Fuse Size (Amps) protecting branch circuit

supplying controller.

Minimum size of single phase 240 V genera-

tor required.

230 Volt

200 Volt

HP

1Ø 2-Wire

1Ø 3-Wire

CentriPro

1

Franklin Grundfos CentriPro Franklin Grundfos CentriPro Franklin Grundfos CentriPro Franklin

½

4.7/4.7 6

6 6.3 6

6 N/A N/A N/A N/A N/A

¾

6.4/6.2 8 8.4 8.3 8 8.4 3.9 3.8 N/A 4.5 4.4

1

9.1/8.1

9.8 9.8 9.7 9.8 9.8 4.7 4.7 N/A 5.5 5.4

1½ 11.0/10.4 13.1

2

13.1

2

11.1 11.5 11.6 6.1 5.9 7.3 7.2 6.8

2 N/A N/A N/A 12.2 13.2

2

13.2

2

7.6 8.1 8.7 8.8 9.3

3 N/A N/A N/A N/A N/A N/A 10.1 10.9 12.2 12 12.5

5 N/A N/A N/A N/A N/A N/A 17.5 17.8 19.8

2

20.2

2

20.5

2

1. CentriPro 2-Wire motors have Generation 1 and Generation 2 amp ratings, see motor nameplate or motor data sticker that was supplied with motor.
2. Amps are higher than controller overload range - use of these motors will limit current and provide reduced performance.