Model mp, mpa, mpai, Description, 1 models – Xylem MPAI User Manual

Page 79: 2 shaft sealing, 3 bearings, 4 approximate value for sound pressure level

Advertising
background image

Installation, Operating and Maintenance Instruction

Model

MP, MPA, MPAI


MP 100-english

page 75

Revision 04

Article No 771074011

Issue 11/2011

3. Description

3.1 Models

Design MP: Horizontal shaft with bearings at both
ends, drive end at discharge side (standard), rotation
clockwise with suction branch left and discharge
branch radially upwards. Grease lubrication.
Optional:

Suction branch right or radially upwards,

discharge branch left or right, drive-end at suction side
(rotation anti-clockwise).

Design MPA: Endsuction type, discharge branch
radially upwards. Drive end at discharge side. Thrust
bearing at drive side, grease lubrication, medium
lubricated slide bearing between first and second
stage.
Optional:

Discharge branch left or right.

MPAI Design: As the MPA design, but also with an
inducer.

The pumps are designed as modular systems and
can, therefore, be delivered in many variants (e.g.
different materials, shaft sealings, different kinds of
lubrication, cooling / heating, a.s.o.).
The permitted application conditions and design
details of the delivered pump are shown in the
attached data sheet and / or order confirmation.

3.2 Shaft Sealing

Basically there are two kinds of shaft sealing: the
packing and the mechanical seal, whereas, there
again are many variants of both kinds. At the data
sheet and / or the order confirmation the shaft sealing
type of your pump is shown.
Instructions for packing a gland can be found in
Section 7.3 and instructions for installation and
operation of mechanical seals in Section 8
"Disassembly of the Pump and Repair".

Further details about packing and mech. seals,
as well as the therewith connected accidental
dangers, you can find in chapter 6.6 and in
chapters 7.2 and 7.3.

In areas endangered to explosion the use of
pumps with packing is forbidden!

3.3 Bearings

Design MP: Bearings at both ends; thrust bearing at
discharge side, ball bearing at suction side.
Lubrication: Grease lubrication (standard design) with
relubricating mechanism (lubricating nipple).

Design MPA, MPAI: Thrust bearing at discharge side,
medium lubricated slide bearing between first and
second stage at suction side.
Lubrication: Grease lubrication (standard design) with
relubricating mechanism (lubricating nipple).




Bearing types

Pump size

Grease lubrication

Bearing type

Suction

side

(only MP)

Discharge side

(MP, MPA, MPAI)

MP/MPA/MPAI 40.2

6306-C3

3306-C3

MP/MPA/MPAI 40.3

6306-C3

3306-C3

MP/MPA/MPAI 65.1 6307-C3

3307-C3

MP/MPA/MPAI 65.2 6307-C3

3307-C3

MP/MPA/MPAI 100.1 6308-C3

2x 7308

(X-

arrangement

)

MP/MPA/MPAI 100.2 6308-C3

2x 7308

(X-

arrangement

)

MP/MPA/MPAI 125.1 6310-C3

2x 7310

(X-

arrangement

)

MP/MPA/MPAI 125.2 6310-C3

2x 7310

(X-

arrangement

)

3.4 Approximate Value for Sound
Pressure Level

Nominal

power

P

N

in kW

Sound pressure level L

pA

in dB(A)

Pump alone

Pump + Motor

2950
min

-1

1450
min

-1

975

min

-1

2950
min

-1

1450
min

-1

975

min

-1

1,5

66,7

65,8

65,3

68,2

66,0

65,5

2,2

68

67

66,5

69,2

67,2

66,7

3

69

68,1

67,6

71,5

68,3

68,5

4

69,9

69

68,5

72,1

69,2

69,2

5,5

71

70

69,5

73,1

70,4

70,1

7,5

71,9

71

70,5

73,7

71,3

71,8

11

73,3

72,3

71,8

75,0

73,2

72,8

15

74,2

73,3

72,8

75,6

74,0

74,0

18,5

74,9

74

73,5

76,1

74,6

76,3

22

75,5

74,5

74

77,1

75,1

76,5

30

76,5

75,6

75,1

77,8

76,1

75,7

37

77,1

76,2

75,7

78,3

76,8

76,4

45

77,9

76,9

76,4

79,4

77,4

76,8

55

78,5

77,5

77

80,1

78,0

77,3

75

79,4

78,5

78

81,4

78,9

78,4

90

80,1

79,1

78,6

81,8

79,4

79,0

110

80,8

79,8

83,4

80,2

132

81,3

80,4

83,7

80,8

160

81,9

81

84,1

81,3

200

82,7

84,6

250

83,4

86,2

315

84,1

86,6

355

84,6

86,9

400

84,9

87,1

450

85,4

87,4

500

85,6

88,3

Sound pressure level L

pA

measured in 1 m distance

from pump surface acc. to DIN 45635, part 1 and 24.
Room and foundation influences are not considered.
The tolerance for these values is ±3 dB(A).
Addition with 60 Hz-operation:
Pump alone: −
Pump with motor: +4 dB(A)




Advertising
This manual is related to the following products:

MPA, MP