Model mp, mpa, mpai, 6 permitted pressures and temperatures – Xylem MPAI User Manual

Page 81

Advertising
background image

Installation, Operating and Maintenance Instruction

Model

MP, MPA, MPAI


MP 100-english

page 77

Revision 04

Article No 771074011

Issue 11/2011

MP, MPA, MPAI Design

Permissible Forces / Torques on the DND

Pressure Joints

Dimension


Vertical Pressure

Joints

Horizontal Pressure

Joints,

Right or Left

MP40.2
MP40.3

MPA40.2

MPAI40.2

MPA40.3

MPAI40.3

DND 40

Fx

330

330

Fy

300

380

Fz

380

300

F

590

590

Mx

280

280

My

140

140

Mz

190

190

M

370

370

MP65.1
MP65.2

MPA65.1

MPAI65.1

MPA65.2

MPAI65.2

DND 65

Fx

560

560

Fy

510

620

Fz

620

510

F

980

980

Mx

350

350

My

200

200

Mz

260

260

M

480

480

MP100.1
MP100.2

MPA100.1

MPAI100.1

MPA100.2

MPAI100.2

DND 100

Fx

900

900

Fy

810

1010

Fz

1010

810

F

1580

1580

Mx

440

440

My

260

260

Mz

330

330

M

610

610

MP125.1
MP125.2

MPA125.1

MPAI125.1

MPA125.2

MPAI125.2

DND 125

Fx

1130

1130

Fy

1010

1250

Fz

1250

1010

F

1970

1970

Mx

570

570

My

350

350

Mz

440

440

M

800

800

The suction and pressure joints must be considered
separately.

If not all loads in effect reach the value limits, one of
these loads may exceed the usual value limit by 1.4
times. The following requirement must be observed
here:

+

2

)

)

/

(

)

/

((

2

.

.

max

2

.

.

max

zul

berechnet

zul

berechnet

M

M

F

F

3.6

Permitted

Pressures

and

Temperatures

In principle, the pressure and temperature values
given in the datasheet and/or order confirmation as
well as the performance label apply. Values (for
pressure and temperature) exceeding these values or
falling below them (for temperature) are not permitted.
If no pressures and/or temperatures are specified in
the data sheet and/or the order confirmation, the
following limits apply for supply pressure and room
temperature:

Supply pressure (system pressure) = Pressure at
the pump intake:

MP design:

max. 40 bar

MPA, MPAI design:

max. 10 bar

Room temperature:

max. 40°C

Also obey the applicable laws and regulations when
using the pump (e.g. DIN 4747 or DIN 4752, Section
4.5).

Curve acc. EN 1092

Max. permissible operating pressure (casing and
flange) applies for the material codes:
111, 211, 311, 262, 411, 462

Curve acc. EN 1092

Max. permissible operating pressure (casing and
flange) applies for the material codes:
532, 141, 341, 151, 351, 672
For the material code used, see the data sheet and/or
the order confirmation.
The specified pressure and temperature limits apply
for standard materials.
The usage limits for other materials are available upon
request.

Advertising
This manual is related to the following products:

MPA, MP