Model mp, mpa, mpai, 2 model mpa, mpai (axial intake lines) – Xylem MPAI User Manual

Page 98

Advertising
background image

Installation, Operating and Maintenance Instruction

Model

MP, MPA, MPAI


MP 100-english

page 94

Revision 04

Article No 771074011

Issue 11/2011

9.2 Model MPA, MPAI (axial intake lines)

See "Appendix" in Operating Instructions for sectional
drawing.

All parts must be cleaned, free of grease and prepared
in accordance with Point 9.1.

Clamp the shaft in a vertical position (24) (use soft

protective wedges), with coupling stub pointing
upwards.

Other assembly work depends on the type of shaft

seal, see Points 4.1 to 4.3, Section Assembly.

Attention: In contrast to the description in Points

4.1 to 4.3, the casing of the shaft seal is exposed.

Proceed carefully in order to avoid damage to the

mechanical seal (GLRD).

Preheat bearing (K1) (max. 80°C) and slide onto

the shaft (24).
Variants: MP, MPA, MPAI 40 and 65 ........roller

bearing (K1) – double row angular ball
bearings (single bearings)
MP, MPA, MPAI 100 and 125 ....roller
bearing (K1) – paired angular ball
bearings in X arrangement

Paired angular ball bearings in X arrangement

Tighten shaft nut (50) while the bearing is still hot.
Fill approx. 60% of the space in the roller bearing

(K1) with grease (when the bearing has cooled
down)

Mount bearing flange (10), at the same time insert

shaft seal casing (18 and 19).

Screw bearing cap (12) to bearing flange (10).
Grease the counter contact surface of the splash

ring packing on the bearing cap (12).

Bring the splash ring (73) into position (groove in

the spacer sleeve) (72).

Lay pressure casing (4) horizontally so that the

shaft can be inserted (24) (mounting plate with
borehole or assembling trestle)

Place pre-mounted unit on the pressure casing (4)

and tighten nuts (M2) (see Supplementary Sheet
for torque)

Rotate shaft (24) to see that it runs smoothly.
The pump must be turned around for further

assembly work (free shaft pointing upwards
vertically)

Assembly as for dismantling.
Lubricate shaft (24)
Check position of the impeller: Insert diffuser

(2/E), slide impeller (1) until impact.

The impeller is in the correct position when the

impeller outlet channel lies within the diffuser
intake channel

(avoids impact losses). Corrections can be carried

out by adding compensation disks or by turning off

the impeller hub on the rear side. This check must
be carried out at every stage.

If a pump is assembled with new impellers, care

must be taken that the first and last stage is
always provided with an impeller with the full blade
diameter. If only one impeller is available with the
full blade diameter it must be used as the first
stage.

Please note that assembly work always starts
with the final stage.

Remove impeller and diffuser once more, insert

O-ring (OR2), re-insert diffuser (2/E).

Insert feather key (PF1 or PF2) for the impeller

that is to be mounted.

Mount impeller (1) (as the O-ring (OR2) presses

on the diffuser (2/E) the setting will not be correct
at first).

Generously grease O-ring (OR1) with silicon

grease and stage casing (60). Do not twist O-ring.

Place stage casing (60) on level and force down

sharply. Hit with a plastic hammer until it impacts.

Assemble pump down to the inside bearing casing

(54).

Slide on bearing sleeve (23), lubricate bearing

surface.

Mount inside bearing casing (54) with bearing

bushing (21) as for stage casing.

Mount first stage of the pump, secure impeller (1)

with washer (29) and nuts (28).

Tighten first nut (28) securely, then turn back by ¼

turn and secure with counter nut.

Mount suction casing (3) with O-ring (OR1), pull

pump with casing armature (25) and nuts (M1)
together slightly.

Align bearing surface of pump feet (place pump

on a flat surface).

Tighten nuts (M1), see table in Appendix for

torque.

Rotate shaft (24) to see that it runs smoothly.

Model MP:

Put off the impeller (1) with washer (29).
Tighten first nut (28) securely, then turn back by ¼

turn and secure with counter nut.

Model MPAI (Sizes 40.1 and 40.2)

Screw on the inducer (101), thereby fix the shaft

on the coupling against twist.

Model MPAI (Sizes 65.1, 65.2, 100.1, 100.2, 125.1
and 125.2)

Insert the key (PF5) and put the inducer (101) off.
Insert the washer (29).
Tighten first nut (28) securely, then turn back by ¼

turn and secure with counter nut.

Mount suction casing (3) with O-ring (OR1), pull

pump with casing armature (25) and nuts (M1)
together slightly.

Align bearing surface of pump feet (place pump

on a flat surface).

Tighten nuts (M1), see table in Appendix for

torque.

Rotate shaft (24) to see that it runs smoothly.

Advertising
This manual is related to the following products:

MPA, MP