0 overview, 1 system diagram, Fig. 2-1, representative system arrangement – Alpha Technologies DSM3 for XM3 - Technical Manual User Manual

Page 10

Advertising
background image

10

745-814-B11-001, Rev. C (03/2014)

All power supply data is stored in the power supply Inverter Module's class information base (CIB) tables in the power supply.

This data is accessible directly via the power supply’s Smart Display (see the power supply’s technical manual for details).

The CIB tables are the source of the Communications Module's data.
The DSM3 Series contains both SCTE-HMS Management Information Base (MIBs) and the proprietary Alpha MIB tables.

The SCTE-HMS MIBs are industry standard MIB tables that store power supply, battery and generator data from the CIB

tables (DSM3x only) (See

Section 6.0, Data Management). The Alpha MIB contains all the data of the SCTE-HMS MIBs

plus additional power supply settings and values as well as DSM3 Series configuration values.
An external generator or additional power supplies may be connected through the COM (AlphaBus) port permitting

monitoring locally through the Ethernet connector or remotely via the Web page or SNMP-based Network Management

System (DSM3x only).

Power supply and Communications Module parameters can be monitored and set locally using a personal computer and a

standard Ethernet cable.

The DSM3 Series transmits data via its cable modem directly over the Coax or Hybrid Fiber Coax network.

The Cable Modem Termination System (CMTS) is the bridge between the cable network and the TCP/IP network. The DSM3

Series’ cable modem communicates directly with the CMTS.

The Dynamic Host Control Protocol (DHCP) server needs to be provisioned with the DSM3’s cable modem CM MAC

address and the MAC address needs to be assigned a DOCSIS Configuration File.

The DOCSIS Configuration File and firmware files should be available in the Root Directory of the Trivial File Transfer

Protocol (TFTP) Server.

The Time of Day (TOD) Server provides the cable modem with the current date and time via the SNTP protocol.

A Network Management System (NMS) or MIB Browser allows remote monitoring of parameter values and changing of

settings in SNMP MIB tables. SCTE-HMS and Alpha MIBs must be installed in the browser. Alarms and traps can be set and

monitored.

The power supply and generator data may be accessed remotely through the Communications Module's Web page by

placing its IP address into a standard Internet Web browser.

The following ports of the Transmission Control Protocol/Internet Protocol network must be opened: 161=SNMP, 162=SNMP,

Traps, 69=TFTP, 80=HTTP.

Power Supply

Local Computer

Coax/HFC Network

CMTS

TCP/IP Network

SNMP-based Network Management System

DHCP Server

1

DSM3

Series

2

External Generator

3

4

5

6

12

TFTP Server

TOD Server

Web Browser

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

Fig. 2-1, Representative System Arrangement

2.0 Overview

2.1

System Diagram

12