0 alpha mib parameters – Alpha Technologies DSM3 for XM3 - Technical Manual User Manual
Page 89
89
745-814-B11-001, Rev. C (03/2014)
10.1
Definitions and Settings
Parameter
OID
Description
Access
Type
Value
ENVIRONMENTAL I/O CONTROLLER
atiMgmtSysIo
1.3.6.1.4.1.926.1.3.2.8
Object Identifier
atiMgmtSysIoSelect
1.3.6.1.4.1.926.1.3.2.8.1
Indicates what function the IO pins are being
used for
Read/Write
Integer
1 = Generic
2 = lapOnly
3 = heaterControlOnly
4 = generatorOnly
5 = heaterControlAndLap
6 = generatorAndLap
atiMgmtSysIoLAPState
1.3.6.1.4.1.926.1.3.2.8.2
Current state of the LAP device
Read Only
Integer
1: notInstalled(1)
2: ok(2)
3: acNotPresent(3)
4: lapBlown(4)
5: lapFail(5)
atiMgmtSysIoGenState
1.3.6.1.4.1.926.1.3.2.8.3
State of the DC Emergency Generator when
sense lines are used
Read Only
Integer
1: notInstalled(1)
2: genOff(2)
3: genRunning(3)
4: genNotDetected(4)
5: error(5)
atiMgmtSysIoPinCtrl
1.3.6.1.4.1.926.1.3.2.8.20
Status of the ENV connector Output Pin
(Pin 3)
Read Only
Integer
1 = Contact Open
2 = Contact Closed
atiMgmtSysIoPinIn4
1.3.6.1.4.1.926.1.3.2.8.21
Status of the ENV connector Input Pin#4
Read Only
Integer
1 = Contact Open
2 = Contact Closed
atiMgmtSysIoPinIn5
1.3.6.1.4.1.926.1.3.2.8.22
Status of the ENV connector Input Pin#5
Read Only
Integer
1 = Contact Open
2 = Contact Closed
atiMgmtSysIoPinIn6
1.3.6.1.4.1.926.1.3.2.8.23
Status of the ENV connector Input Pin#6
Read Only
Integer
1 = Contact Open
2 = Contact Closed
CABLEWARE MANAGER
atiMgmtSysPhoneHomeIp
1.3.6.1.4.1.926.1.3.2.5
Object Identifier
atiMgmtSysPhoneHomeIp
1.3.6.1.4.1.926.1.3.2.5.1.0
Address for the Phone Home Frame
Read/Write
IP Address
0.0.0.0
atiMgmtSysPhoneHomeForce
1.3.6.1.4.1.926.1.3.2.5.2.0
Forces one Phone Home message
regardless of timers
Read/Write
Integer
1=No Operation (default)
2=Force
atiMgmtSysPhoneHomeTimer
1.3.6.1.4.1.926.1.3.2.5.3.0
Time since last frame transmitted, zero
means never transmitted
Read Only
Time Ticks
GENERAL CONTROLS
atiMgmtSysTamperPolarity
1.3.6.1.4.1.926.1.3.2.6.1.0
Determines when tamper is active
Read/Write
Integer
1=doorOpenWhenContactOpen
2=doorOpenWhenContactClosed
(Default)
atiMgmtSysAlphaBusSize
1.3.6.1.4.1.926.1.3.2.6.2.0
Internal microprocessor communications bus
size. Alpha XM3 series power supplies use
9 bit. Alpha GMX and VMX series supplies
use 8 bit
Read/Write
Integer
1=9 Bit (default)
2=8 Bit
atiMgmtSysBatteryCalMode
1.3.6.1.4.1.926.1.3.2.6.3.0
This parameter determines which of the
calibration tables to use in cases where the
battery negative is tied to ground or when
it floats.
Read/Write
Integer
1=Float
2=Negative
atiMgmtSysAlphaBusSpeed
1.3.6.1.4.1.926.1.3.2.6.4.0
Select the speed at which the AlphaBus will
communicate
Read/Write
Integer
1=baud9600
2=baud57600
atiMgmtSysGnrlInfoConfigs
1.3.6.1.4.1.926.1.3.2.7.1
Object Identifier
atiMgmtSysGnrlInfoConfigsMain
1.3.6.1.4.1.926.1.3.2.7.1.1.0 An ASCII string programmed into the main
board non-volatile memory
Read Only
Octet String
Product number, configuration
number serial number, etc.
atiMgmtSysGnrlInfoConfigsDaughter
1.3.6.1.4.1.926.1.3.2.7.1.2.0 An ASCII string programmed into the C/D
battery circuitry (DSM3x only)
Read Only
Octet String
Product number, configuration
number serial number, etc.
atiMgmtSysGnrlInfoConfigsBase
1.3.6.1.4.1.926.1.3.2.7.1.3.0 An ASCII string describing the base
configuration of the device
Read Only
Octet String
i.e. DSM3, DSM3x
10.0 Alpha MIB Parameters