Multi-shot, Iso_enable / free-run, Asynchronous broadcast – ALLIED Vision Technologies Marlin F-201 User Manual

Page 125: See chapter

Advertising
background image

Controlling image capture

MARLIN Technical Manual V2.4.0

125

Multi-Shot

Setting multi-shot and entering a quantity of images in Count_Number in
the 61Ch register enables the camera to record a specified number of images.

The number is indicated in bits 16 to 31. If the camera is put into Iso_Enable
mode (see Chapter

ISO_Enable / Free-Run

on page 125), this flag is ignored

and deleted automatically once all the images have been recorded.

If multi-shot mode is activated and the images have not yet all been cap-
tured, it can be cancelled by resetting the flag. The same result can be
achieved by setting the number of images to 0.

Multi-shot can also be combined with the external trigger in order to grab a
certain number of images based on an external trigger. This is especially
helpful in combination with the so called Deferred_Mode to limit the num-
ber of grabbed images to the FIFO size.

ISO_Enable / Free-Run

Setting the MSB (bit 0) in the 614h register (ISO_ENA) puts the camera into
ISO_Enable mode or Continuous_Shot (free-run). The camera captures an
infinite series of images. This operation can be quit by deleting the 0 bit.

Asynchronous broadcast

The camera accepts asynchronous broadcasts. This involves asynchronous
write requests that use node number 63 as the target node with no
acknowledge.

This makes it possible for all cameras on a bus to be triggered by software
simultaneously - e.g. by broadcasting a one-shot. All cameras receive the
one_shot command in the same IEEE 1394 bus cycle. This creates uncer-
tainty for all cameras in the range of 125 µs.

Inter-camera latency is described in Chapter

Jitter at start of exposure

on

page 126.