Auto shutter control, Auto gain control, Auto shutter control auto gain control – ALLIED Vision Technologies Marlin F-201 User Manual

Page 221: Table, Advanced register: auto shutter control, Advanced register: auto gain control, Table 115: advanced register: auto shutter, Control, Table 116: advanced register: auto gain con, Trol

Advertising
background image

Configuration of the camera

MARLIN Technical Manual V2.4.0

221

Auto shutter control

The table below illustrates the advanced register for auto shutter control.
The purpose of this register is to limit the range within which auto shutter
operates.

Auto gain control

The table below illustrates the advanced register for auto gain control.

MinValue and MaxValue limits the range the auto gain feature is allowed to
use for the regulation process. Both values are initialized with the minimum
and maximum value defined in the standard GAIN_INQ register.

Changing the auto gain range might not affect the regulation, if the regu-
lation is in a stable condition and no other condition affecting the image
brightness is changed.

If both auto gain and auto shutter are enabled and if the gain is at its lower
boundary and shutter regulation is in progress, decreasing the lower auto
gain boundary has no effect on auto gain/shutter regulation as long as auto
shutter regulation is active.

Both values can only be changed within the range defined by the standard
GAIN_INQ register.

Register

Name

Field

Bit

Description

0xF1000360

AUTOSHUTTER_CTRL Presence_Inq

[0]

Indicates presence of this fea-
ture (read only)

---

[1..31]

Reserved

0xF1000364

AUTOSHUTTER_LO

Min Value

[0..31]

Minimum value

0xF1000368

AUTOSHUTTER_HI

Max Value

[0..31]

Maximum value

Table 115: Advanced register: Auto shutter control

Register

Name

Field

Bit

Description

0xF1000370 AUTOGAIN_CTRL

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..3]

Reserved

Max Value

[4..15]

Maximum auto gain value

---

[16..19]

Reserved

Min value

[20..31]

Minimum auto gain value

Table 116: Advanced register: Auto gain control