Color correction, Trigger delay, Color correction trigger delay – ALLIED Vision Technologies Marlin F-201 User Manual

Page 223: Table 119: advanced register: color correction, Table 120: advanced register: trigger delay

Advertising
background image

Configuration of the camera

MARLIN Technical Manual V2.4.0

223

E.g. if the active image size is 640 x 480 pixel the camera accepts a maximum
of 640 x 512 pixel as the auto function AOI work area (if the control area
position is 0:0).

Another case is for outdoor applications: the sky will be excluded from the
generation of the reference levels.

Color correction

For an explanation of the color correction matrix and for further information
read Chapter

Color interpolation and correction

on page 104.

Trigger delay

The advanced register allows start of the integration to be delayed via
DelayTime by max. 2

21

µs, which is max. 2.1 s after a trigger edge was

detected.

Register

Name

Field

Bit

Description

0xF10003A0 COLOR_CORR

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..5]

Reserved

ON_OFF

[6]

Color correction on/off

default: on

Write: 02000000h to switch
color correction OFF

Write: 00000000h to switch
color correction ON

---

[7..31]

Reserved

Table 119: Advanced register: Color correction

Register

Name

Field

Bit

Description

0xF1000400 TRIGGER_DELAY

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..5]

Reserved

ON_OFF

[6]

Trigger delay on/off

---

[7..10]

Reserved

DelayTime

[11..31]

Delay time in µs

Table 120: Advanced register: Trigger Delay