Test images, Table 105: advanced register: test image – ALLIED Vision Technologies Marlin F-201 User Manual

Page 211

Advertising
background image

Configuration of the camera

MARLIN Technical Manual V2.4.0

211

Test images

Bits 8-14 indicate which test images are saved. Setting bits 28-31 activates
or deactivates existing test images.

auto gain

auto shutter

auto white balance

Register

Name

Field

Bit

Description

0xF1000210

TEST_IMAGE

Presence_Inq

[0]

Indicates presence of this feature (read
only)

---

[1..7]

Reserved

Image_Inq_1

[8]

Presence of test image 1
0: N/A
1: Available

Image_Inq_2

[9]

Presence of test image 2
0: N/A
1: Available

Image_Inq_3

[10]

Presence of test image 3
0: N/A
1: Available

Image_Inq_4

[11]

Presence of test image 4
0: N/A
1: Available

Image_Inq_5

[12]

Presence of test image 5
0: N/A
1: Available

Image_Inq_6

[13]

Presence of test image 6
0: N/A
1: Available

Image_Inq_7

[14]

Presence of test image 7
0: N/A
1: Available

---

[15..27] Reserved

TestImage_ID

[28..31] 0: No test image active

1: Image 1 active
2: Image 2 active

Table 105: Advanced register: Test image