Look-up tables (LUT)

Load the look-up tables to be used into the camera and choose the look-up
table number via the LutNo field. Now you can activate the chosen LUT via
the LUT_CTRL register.

The LUT_INFO register indicates how many LUTs the camera can store and
shows the maximum size of the individual LUTs.

The possible values for LutNo are 0..n-1, whereas n can be determined by
reading the field NumOfLuts of the LUT_INFO register.

Register

Name

Field

Bit

Description

0xF1000240

LUT_CTRL

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..5]

Reserved

ON_OFF

[6]

Enable/Disable this feature

---

[7..25]

Reserved

LutNo

[26..31] Use look-up table with LutNo

number

0xF1000244

LUT_MEM_CTRL

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..4]

Reserved

EnableMemWR

[5]

Enable write access

---

[6..7]

Reserved

AccessLutNo

[8..15]

Reserved

AddrOffset

[16..31] byte

0xF1000248

LUT_INFO

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..7]

Reserved

NumOfLuts

[8..15]

Maximum number of look-up
tables

MaxLutSize

[16..31] Maximum look-up table size

(bytes)

Table 107: Advanced register: LUT