Configuration of the camera

MARLIN Technical Manual V2.4.0

228

Advanced register: frame counter

The frame counter feature is controlled by the following advanced feature
register:

Having this feature enabled, the current frame counter value (images read
out of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit
integer value into any captured image.

Setting the Reset flag to 1 resets the frame counter to 0 — the Reset flag
is self-cleared.

The ON_OFF and LinePos fields are simply mirrors of the time stamp feature.
Settings of these fields are applied to all image stamp features.

Additionally there is a register for direct read out of the frame counter value.

Register

Name

Field

Bit

Description

0xF1000610 FRMCNT_STAMP

Presence_Inq

[0]

Indicates presence of this
feature (read only)

Reset

[1]

Reset frame counter

---

[2..5]

Reserved

ON_OFF

[6]

SIS (time stamp) on/off

---

[7]

Reserved

---

[8..15]

Reserved

LinePos

[16..31]

Line position of SIS (time
stamp)

0xF1000614 FRMCNT

[0..31]

Frame counter

Table 126: Advanced register: Frame counter