Advanced register: trigger counter

The trigger counter feature is controlled by the following advanced feature
register:

Having this feature enabled, the current trigger counter value (external trig-
ger seen by hardware) will be inserted as a 32-bit integer value into any cap-
tured image.

Setting the Reset flag to 1 resets the trigger counter to 0 – the Reset flag
is self-cleared.

The ON_OFF and LinePos fields are simply mirrors of the time stamp feature.
Settings of these fields are applied to all image stamp features.

Additionally there is a register for direct read out of the trigger counter
value.

Register

Name

Field

Bit

Description

0xF1000620 TRGCNT_STAMP

Presence_Inq

[0]

Indicates presence of this
feature (read only)

Reset

[1]

Reset trigger counter

---

[2..5]

Reserved

ON_OFF

[6]

SIS (time stamp) on/off

---

[7]

Reserved

---

[8..15]

Reserved

LinePos

[16..31]

Line position of SIS
(time stamp)

0xF1000624 TRGCNT

[0..31]

Trigger counter

Table 127: Advanced register: Trigger counter

Note

L

The 4 bytes of the trigger counter value will be inserted as
the 9th to 12th byte of a line.