Reset of error codes – ALLIED Vision Technologies Marlin F-201 User Manual

Page 233

Advertising
background image

Configuration of the camera

MARLIN Technical Manual V2.4.0

233

Reset of error codes

The ErrorCode field is set to zero on the next write access.

You may also reset the ErrorCode

by writing 00000000h to the USER_PROFILE register.

Note

L

A profile save operation automatically disables captur-
ing of images.

A profile save or restore operation is an uninterruptable
(atomic) operation – the write response (of the asyn-
chronous write cycle) will be sent after completion of
the operation.

Restoring a profile will not overwrite other settings
than listed above.

If a restore operation fails or the specified profile does
not exist, all registers will be overwritten with the
hard-coded factory defaults (profile #0).

Data written to this register is not reflected in the
standard memory channel registers.