1-11

Section 1 - Introduction

Installation and Operation Manual
X-TMF-SLAMf-MFC-eng
Part Number: 541B032AAG
April, 2013

Brooks

®

Digital MFC's and MFM's

Certifications:

EMC Directive 89/336/EEC:

Per EN 61326

Enclosure: Type 4X / IP66

Ambient Temperature: 0

0

F > Tamb < 150

0

F, (0

0

C > Tamb < 65

0

C)

Hazardous Location Classification

United States and Canada - Non incendive

UL Listed: E73889 Volume 1, Section 25

UL Recognized: E73889 Volume 3, Section 4

Class I, Division 2, Groups A, B, C, D, F and G; T4

Class I, Zone 2, AEx nA II T4

Per ANSI/ISA 12.12.02 - 2003 and ANSI/UL 60079 - 15

Ex nA II T4

Per CSA - E79 - 15

Europe - ATEX Directive 94/9/EC - Non Sparking

KEMA 04ATEX1290X

II 3 G Ex nA II T4

II 3 D Ex tD A22 IP66 T 85

0

C

Per EN 60079-0: 2006; EN 60079-15: 2005:

EN 61241-0: 2006; EN 61241-1: 2004

IECEx-Non Sparking

KEM 08.0043X

Ex nA II T4

Ex tD IP66 T 85

0

C

Per IEC 60079-0: 20044; IEC 60079-15: 2005;

IEC 61241-0: 2004; IEC 61241-1: 2004

Instructions for Safe Use:

United States and Canada: A Class 2 Power Supply must be used.

ATEX and IECEx:

1. Provisions shall be made to prevent the rated voltage from being

exceeded by transient disturbances of more than 40%.

2. When the temperature under rated conditions exceeds 70

0

C at the

cable or conduit entry point, or 80

0

C at the branching point of the

conductors, the temperature specification of the selected cable shall be in
compliance with the actual measured temperature values.

Pressure Equipment Directive (97/23/EC)