TechnicalData

control pressure for control function a
The values are valid for
• VA tube-formed body with welded nozzles in accordance with

DIN 11850 series 2, with OD weld-on ends, with ANSI and JIS
welding neck flange

connection

size

dn

[mm]

actuator size

[mm]

control pressure [bar]

for medium pressure

0 bar

maximum

10

40

5

4

15

50

5

3.5

63

5

4

20

50

5

3.5

63

5

4

25

63

5

4

80

5.5

4

32

63

5

4.5

32

80

5.5

4.5

40

100

5.5

4

50

100

5.5

4

125

5.5

4

65

125

5.5

4.5

Tab. 8: Control pressure CFA

6.4.4 minimum control pressure

required minimum control pressure depending on medium
pressure
The values apply to body made of
• Plastic
• All models with VA forged steel and VA precision casting
• VA tube-formed body with socket, DIN welding neck flange and

weld-on ends in accordance with EN ISO 1127 (ISO 4200)

control function B (cfB)

noTe!

important for the service life of the diaphragm!
• Do not select control pressure higher than required.

DN20,

Ø

80

0

2

4

6

8

10

0 1 2 3 4 5 6 7 8 9 10

DN15,

Ø

63

DN8,

Ø

40

DN15,

Ø

50

DN25,

Ø

80

DN25,

Ø

63

DN20,

Ø

63

Medium pressure [bar]

Control pressure [bar]

CFB / EPDM

Actuator size

Orifice

(Diaphragm size)

Fig. 4: Control function B, elastomer diaphragm, actuators