Burkert Type 2037 User Manual

Page 31

Advertising
background image

31

Repairs

4 fastening

screws

Diaphragm

Body

Lower control air con-
nection
(for CFA and CFI)

Upper control air con-
nection
(for CFB and CFI)

Mark tab for direction

of flow

example

Fig. 31: Replacement of diaphragm

replacement of the diaphragm for control function a

→

Clamp the valve body in a holding device (applies only to valves
not yet installed).

→

Pressurize lower control air connection with compressed air (value
as indicated on the type label) (see picture below “Fig. 32: Control
air connection”)
. This is required to detach the diaphragm without
damage from the body.

→

Loosen fastening screws crosswise and remove actuator together
with diaphragm from the body.

→

Unbutton or unscrew the old diaphragm. If attachment is with a
bayonet catch, remove the diaphragm by rotating it through 90°
(see “Tab. 10: Fastening types for diaphragms”).

→

Install new diaphragm in actuator (see “Tab. 10: Fastening types
for diaphragms”
).

→

Align diaphragm.
Observe mark tab for direction of flow!

→

Place actuator back on the body.

→

Lightly cross-tighten the body screws until the diaphragm is
between the body and actuator.
do not tighten the screws yet.

→

Actuate the diaphragm valve twice to position the diaphragm
correctly.

→

Without applying pressure, tighten the body screws to the per-
mitted tightening torque (see “Tab. 11: Tightening torques for
diaphragms”
).

→

Pressurize lower control air connection with compressed air (value
as indicated on the type label).

→

Check the tightening torque of the screws again.