Below “fig. 32: control air connection”), Tab. 11: tightening torques for diaphragms – Burkert Type 2037 User Manual

Page 32

Advertising
background image

32

Repairs

replacement of the diaphragm for control functions B and i

→

Clamp the valve body in a holding device (applies only to valves
not yet installed).

→

Loosen the fastening screws crosswise and remove actuator
together with diaphragm from the body.

→

Unbutton or unscrew old diaphragm. If attachment is with a bayonet
catch, remove the diaphragm by rotating it through 90° (see “Tab.
10: Fastening types for diaphragms”
).

→

Install new diaphragm in actuator (see “Tab. 10: Fastening types
for diaphragms”
).

→

Align diaphragm.
Observe mark tab for direction of flow!

→

Place actuator back on the body.

→

Lightly cross-tighten the body screws without pressurization until
the diaphragm is between the body and actuator.
do not tighten the screws yet.

→

Pressurize upper control air connection with compressed air
(value as indicated on the type label) (see “Fig. 32: Control air
connection”
).

→

Actuate the diaphragm valve twice.

→

Tighten the body screws to the permitted tightening torque (see
“Tab. 11: Tightening torques for diaphragms”).

Lower control air connection
(for CFA and CFI)

Upper control air connection
(for CFB and CFI)

Fig. 32: Control air connection

Orifice

(Diaphragm size)

[mm]

tightening torques for diaphragms [nm]

epdm / fkm

ptfe / advanced ptfe /

laminated advanced ptfe

8

2

2.5

15

3.5

4

20

4

4.5

25

5

6

32

6

8

40

8

10

50

12

15

65

20

30

Tab. 11: Tightening torques for diaphragms

english

Type 2030, 2031, 2031 K, 2032,

2033, 2037

Advertising