Below “fig. 32: control air connection”), Tab. 11: tightening torques for diaphragms – Burkert Type 2037 User Manual

Page 32

Advertising
background image

32

Repairs

replacement of the diaphragm for control functions B and i

Clamp the valve body in a holding device (applies only to valves
not yet installed).

Loosen the fastening screws crosswise and remove actuator
together with diaphragm from the body.

Unbutton or unscrew old diaphragm. If attachment is with a bayonet
catch, remove the diaphragm by rotating it through 90° (see “Tab.
10: Fastening types for diaphragms”
).

Install new diaphragm in actuator (see “Tab. 10: Fastening types
for diaphragms”
).

Align diaphragm.
Observe mark tab for direction of flow!

Place actuator back on the body.

Lightly cross-tighten the body screws without pressurization until
the diaphragm is between the body and actuator.
do not tighten the screws yet.

Pressurize upper control air connection with compressed air
(value as indicated on the type label) (see “Fig. 32: Control air
connection”
).

Actuate the diaphragm valve twice.

Tighten the body screws to the permitted tightening torque (see
“Tab. 11: Tightening torques for diaphragms”).

Lower control air connection
(for CFA and CFI)

Upper control air connection
(for CFB and CFI)

Fig. 32: Control air connection

Orifice

(Diaphragm size)

[mm]

tightening torques for diaphragms [nm]

epdm / fkm

ptfe / advanced ptfe /

laminated advanced ptfe

8

2

2.5

15

3.5

4

20

4

4.5

25

5

6

32

6

8

40

8

10

50

12

15

65

20

30

Tab. 11: Tightening torques for diaphragms