Malfunctions

12

malfuncTiOns

malfunction

cause / remedial action

Actuator
does not
switch

Control connection interchanged *
CFA

→

Connect lower control connection

CFB

→

Connect upper control connection

CFI

→

Upper control connection: Close
Lower control connection: Open

* see “Fig. 32: Control air connection”

Control pressure too low

→

See pressure specifications on the type label.

Medium pressure too high

→

See pressure specifications on the type label.

Valve is not
sealed

Medium pressure too high

→

See pressure specifications on the type label.

Control pressure too low

→

See pressure specifications on the type label.

Flow rate
reduced

PTFE diaphragm bulging

→

Replace diaphragm.

13

spare parTs

Warning!

risk of injury when opening the actuator body!
The actuator contains a tensioned spring. If the body is opened,
there is a risk of injury from the spring jumping out!

▶ Carefully open the actuator body and hold it in such a way that any

parts which jump out cannot injure anyone or damage anything.

CauTion!

risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.

▶ Use only original accessories and original spare parts from

Bürkert.

Types 2030, 2031, 2031 K, 2032 and 2033 are available as spare
parts for the piston-controlled diaphragm valves.
• Seal set,
• Diaphragm.

english

Type 2030, 2031, 2031 K, 2032,

2033, 2037

Advertising
This manual is related to the following products: