TechnicalData

Medium pressure [bar]

Control pressure [bar]

CFI / PTFE-EPDM

Actuator size

Orifice

(Diaphragm size)

0

2

4

6

8

10

0 1 2 3 4 5 6 7 8 9 10

DN40,

Ø

125

DN32,

Ø

100

DN40,

Ø

100

DN50,

Ø

100

DN50,

Ø

125

DN65,

Ø

125

Fig. 11: Control function I, PTFE EPDM diaphragm,

actuators ø 100 – 125 mm

required minimum control pressure depending on medium
pressure
The values are valid for
• VA tube-formed body with weld-on ends in accordance with DIN

11850 series 2 as well as with OD weld-on ends, with ANSI and
JIS welding neck flange

control function B (cfB)

noTe!

important for the service life of the diaphragm!
• Do not select control pressure higher than required.

DN20,

Ø

63

0

2

4

6

8

10

0 1 2 3 4 5 6 7 8 9 10

DN15,

Ø

63

DN8,

Ø

40

DN15,

Ø

40

DN15,

Ø

50

DN25,

Ø

63

DN20,

Ø

50

DN32,

Ø

63

Medium pressure [bar]

Control pressure [bar]

CFB / EPDM

Actuator size

Orifice

(Diaphragm size)

Fig. 12: Control function B, EPDM diaphragm,

actuators ø 40 – 63 mm