Chapter 7 - Using the LCD for Configuration and Management

110

Campus-REX2 RS Interface Card User Manual

Configuring Alarm Thresholds

Alarm thresholds determine the level at which an alarm condition is reached.
There are two types of HDSL alarm thresholds:

Link ES threshold determines the number of errored seconds that must
occur to trigger an alarm. This threshold can be set to 17 or 170 errored
seconds. You can also disable this alarm.

Margin threshold determines the margin, in dB, that triggers an alarm.
This threshold can be set anywhere between 1 dB and 25 dB, in 1 dB
increments. You can also disable this alarm.

To set the alarm thresholds:

1

From the

CURRENT ALARMS

display, press Next.

HDSL LINK

ALARMS

is displayed.

2

Press Enter. The current HDSL alarm status is displayed.

3

Press Next.

HDSL ES THRESHLD

is displayed.

4

Press Enter.

5

Press Next to scroll through the settings for the ES threshold until the
preferred setting is displayed.

6

Press the Enter button to select the preferred setting.

HDSL ES

THRESHLD

is displayed.

7

Press Next.

MARGIN THRESHLD

is displayed.

8

Press Enter.

9

Press Next to scroll through the settings for the margin threshold until the
preferred setting is displayed.

10

Press Enter to select the preferred setting.

MARGIN THRESHLD

is

displayed.