Chapter 7 - Using the LCD for Configuration and Management

112

Campus-REX2 RS Interface Card User Manual

Configuring the Alarm

To enable or disable the local Loss of Signal alarm:

1

From the

CURRENT ALARMS

display, press Next twice.

LOCAL I/F

ALARMS CONFIG & STATUS

is displayed.

2

Press Enter. The current status of the local alarm is displayed.

3

Press Next.

LOC LOSS OF SIG ALM

is displayed.

4

Press Enter.

5

Press Next to scroll through the settings for the alarm.

6

Press Enter to select the preferred setting.

LOC LOSS OF SIG ALM

is displayed.

Remote Alarms

Loss of Signal (LOS) alarms can occur on the remote unit. This section
describes how to view and configure this alarm.

Viewing Current Alarms

If the

CURRENT ALARMS

display indicates a remote alarm, you can

determine the alarm type:

1

From the

CURRENT ALARMS

display, press Next three times.

RMT I/F

ALARMS CONFIG & STATUS

is displayed.

2

Press Enter. The current status of the remote alarm is displayed.

Configuring the Alarm

To enable or disable the remote Loss of Signal alarm:

1

From the

CURRENT ALARMS

display, press Next three times.

RMT I/F

ALARMS

is displayed.

2

Press Enter. The current status of the remote alarm is displayed.

3

Press Next.

LOSS OF SIG ALM

is displayed.