Configuring trap receivers – ADC Campus-REX2 RS User Manual

Page 75

Advertising
background image

Chapter 3 - Configuring the REX2

Campus-REX2 RS Interface Card User Manual

63

Configuring Trap Receivers

The Campus-REX2 sends traps to devices on the network, which you
configure as trap receivers, when events or alarms occur. The following are
traps that the Campus-REX2 can issue:

coldStart

warmStart

linkDown

linkUp

authenticationFailure

Configure the trap receivers as follows:

1

Do the following to enter an IP address and a community string for each
of three trap receivers that you can configure:

a

To enter the IP address for a device on the network that will receives
traps issued by Campus-REX2, type

,

, or

+

then press

. At the prompt, enter the IP address:

Required format is nnn.nnn.nnn.nnn

Enter Trap Receiver x IP Address: 172.150.100.12

b

To enter the community string for a device on the network that will
receives traps issued by Campus-REX2, type

,

+

, or

+

then press

. At the prompt, enter the community string that

can be up to 64 ASCII characters:

Maximum length is 64 characters.

Enter Trap Receiver 1 Community String: rcvr1

2

Repeat

Step 1

for each trap receiver you want to configure.

3

Type

to return until you return to the Bridge or Router

Configuration screen.

4

If you are changing only SNMP parameters, go to

“Saving the Bridge

Configuration” on page 40

or

“Saving the Router Configuration” on

page 55

to save your changes.

7

9

1

1

ENTER

8

1

0

1

2

ENTER

R

Advertising