Initiating a loopback, Clearing a loopback, Setting the loopback timeout – ADC Campus-REX2 RS User Manual

Page 126

Advertising
background image

Chapter 7 - Using the LCD for Configuration and Management

114

Campus-REX2 RS Interface Card User Manual

Initiating a Loopback

To initiate a loopback condition:

1

From the

LOOPBACK MODE

display, press Enter.

2

Press Next to scroll through the loopback options until the preferred
loopback condition is displayed.

3

Press Enter to initiate the loopback.

LOOPBACK MODE

is displayed.

Clearing a Loopback

To clear a loopback condition:

1

From the

LOOPBACK MODE

display, press Enter.

2

Press Next to scroll through the loopback options until

NONE

is

displayed.

3

Press Enter to clear the loopback.

LOOPBACK MODE

is displayed.

Setting the Loopback Timeout

The loopback timeout determines the amount of time before a loopback clears
automatically. To set a loopback timeout:

1

From the

LOOPBACK MODE

display, press Next.

LOOPBACK

TIMEOUT

is displayed.

2

Press Enter to access the loopback timeout options.

3

Press Next to scroll through the options until the preferred setting
appears.

4

Press Enter to select the option and return to the

LOOPBACK TIMEOUT

display.

If you set the loopback timeout to

NONE

, loopbacks run until

you clear them manually or turn the unit off.