Chapter 7 - Using the LCD for Configuration and Management

Campus-REX2 RS Interface Card User Manual

111

Viewing 24-Hour HDSL Alarm History

You can view the number of HDSL alarm conditions that have occurred over
the past 24 hours. The LCD displays 24-hour information for the following
alarms:

local errored seconds (

LOCAL ES

)

remote errored seconds (

REMOTE ES

)

local unavailable seconds (

LOCAL UAS

)

remote unavailable seconds (

REMOTE UAS

)

You may also view the time when the counter was last cleared and clear the
counter.

To view the HDSL alarm history:

1

Press Escape until

CAMPUS RS I/F: REX2

is displayed.

2

Press Next.

HDSL LINK CONFIG & STATUS

is displayed.

3

Press Enter, then press Next until

PERFORMANCE STATUS

is

displayed.

4

Press Enter, then press Next to scroll through the alarm history is
displayed.

5

To reset the counter, press Next until

Press ENTER to clear

error cnts

is displayed, then press Enter.

Local Alarms

Loss of Signal (LOS) alarms can occur on the local unit. This section
describes how to view and configure this alarm.

Viewing Current Alarms

If the

CURRENT ALARMS

display indicates a local alarm, you can determine

the alarm type:

1

From the

CURRENT ALARMS

display, press Next twice.

LOCAL I/F

ALARMS CONFIG & STATUS

is displayed.

2

Press Enter. The current status of the local alarm is displayed.