15

POWER WIRING

WIRING

POWER WIRING

This operator can be wired for either 120 Vac or 240 Vac or a solar

panel (not provided). Follow the directions according to your application.

For dual gate applications, power will have to be connected to each

operator. Main power supply and control wiring MUST be run in

separate conduits.

240 VAC ONLY

If using the 240 Vac option a heater cannot be used. The accessory outlet is disabled

and cannot be used with the 240 Vac option.

1

Remove the outlet housing from the electrical box by removing the screws

(2).

2

Pull the outlet housing out and locate the power wiring connector on the EMI

board.

3

Unplug the power wiring connector from the 120 Vac socket (factory default

location) and plug it into the 240 Vac socket.

4

Replace the outlet housing by securing with the screws. The operator is now

set for 240 Vac operation.

Outlet Housing

Power Wiring Connector

(120 Vac Socket, factory default)

240 Vac Socket

NUMBER OF CYCLES PER DAY

Slide Gate Installation (16 ft. 1000 lb. gate)

Accessories

Single Gate

Solenoid Lock

50 mA

100 mA

300 mA

7AH Batteries

(standard)

33AH Batteries

(optional)

TRANSFORMER

POWERED

Continuous

Continuous

Continuous

Continuous

Continuous

Continuous

Continuous

Continuous

Continuous

Continuous

BATTERY

POWERED

100

275

35

230

45

270

45

270

40

260

AMERICAN WIRE

GAUGE (AWG)

MAXIMUM WIRE

LENGTH (120 VAC)

MAXIMUM WIRE

LENGTH (240 VAC)

14

130 feet

260 feet

12

205 feet

410 feet

10

325 feet

650 feet

8

520 feet

1040 feet

6

825 feet

1650 feet

4

1312 feet

2624 feet

AC POWER SWITCH

The AC Power switch on the operator will turn the incoming 120/240 Vac power ON

or OFF. The operator's AC Power switch ONLY turns off AC power to the control board

and DOES NOT turn off battery power.

AC Power Switch

EMI Board

NOTE: Use copper conductors ONLY.

Advertising