INITIAL LIMITS AND FORCE ADJUSTMENT

For dual gate applications the limits will have to be set for each

operator. The gate MUST be attached to the operator before setting the

limits and force.
Ensure the gate is closed.

1

Press the SET OPEN and SET CLOSE buttons simultaneously to enter limit

setting mode.

2

Press and hold the OPEN or CLOSE button on the remote control until the gate

reaches the desired open position. The gate can be jogged back and forth

using the OPEN and CLOSE buttons on the remote control.

3

Once the gate is in the desired open position, press and release the STOP

button on the remote control.

4

Press and release the OPEN button on the remote control again to set the

open limit.

5

Press and hold the CLOSE or OPEN button on the remote control until the gate

reaches the desired close position. The gate can be jogged back and forth

using the OPEN and CLOSE buttons on the remote control.

6

Once the gate is in the desired close position, press and release the STOP

button on the remote control.

7

Press and release the CLOSE button on the remote control again to set the

close limit.

8

Cycle the gate open and close. This automatically sets the force.

When limits are set properly the operator will automatically exit limit setting mode.

LIMIT SETUP WITH A REMOTE CONTROL

LIMIT SETUP WITH A REMOTE CONTROL

ADDITIONAL FEATURES

To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming

section.

ALARM

RESET

SET OPEN SET CLOSE

OFF

BIPART

DELAY

PRESS &

RELEASE

TO BEGIN

3-Button Remote Control programmed for OPEN, CLOSE, and STOP

Advertising