Troubleshooting, Input leds, Status leds – Controlled Products Systems Group CSL24VH User Manual

Page 37: Control board leds, Diagnostic codes leds

Advertising
background image

35

INPUT LEDS

OPEN INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

CLOSE INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

STOP INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

FIRE DEPT

INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

OPEN SAFETY

INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

CLOSE SAFETY

INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

STATUS LEDS

INPUT POWER OFF

OFF state

ON

AC charger or Solar power available

BATT

CHARGING

OFF

Not charging

ON

Trickle charge

FAST BLINK

High current charge

FASTER BLINK

Over voltage error

TIMER

OFF

The timer is disabled

ON

The timer is enabled

MEDIUM BLINK

The timer is running

FAST BLINK

The timer is paused

FASTER BLINK

The timer is cancelled

GATE MOVING OFF

The gate is stopped

ON

The gate is opening or closing

FASTEST BLINK

The operator is in E2

BATT LOW

OFF

No battery error

ON

Battery low error

MEDIUM BLINK

Battery critically low error

FAST BLINK

Battery disconnected error

FASTEST BLINK

Charging, extreme temperature, or over

voltage error

ACC PWR OVLD OFF

OFF state

ON

Accessory overload protector opened

CONTROL BOARD LEDS

TROUBLESHOOTING

CONTROL BOARD LEDS

YELLOW DIAGNOSTIC LED

# BLINKS

MEANING

CORRECTION

1 BLINK

Low Power Mode

(not an error)

2 BLINKS

ID resistor failure

Check ID resistor wiring, clear limit

settings and reset limits

3 BLINKS

Exceeded Maximum

Run Timer

Check gate travel, if necessary adjust

force setting

5 BLINKS

RPM (obstruction)

Check for obstruction, if necessary

adjust force setting

6 BLINKS

Current (obstruction) Check for obstruction, if necessary

adjust force setting

7 BLINKS

Position failure

Check gate travel, clear limit settings

and reset limits

12 BLINKS

Loop Error

One of the loops is in error. Refer to the

loop detector to determine the error.

RED DIAGNOSTIC LED

# BLINKS

MEANING

CORRECTION

2 BLINKS

Current Sense

Motor control circuit fault, replace

control board

3 BLINKS

FET Failure

Motor control circuit fault, replace

control board

4 BLINKS

RAM Failure

Memory failure, replace control board

5 BLINKS

Flash Memory

Failure

Memory failure, replace control board

6 BLINKS

EEPROM Failure

Memory failure, replace control board

7 BLINKS

Watchdog Failure Controller failure, replace control board

8 BLINKS

Brownout

Check power harness or line voltage

9 BLINKS

Fail

Control Board failure

10-14 BLINKS Software Failure

Cycle power to the control board. If

continues replace control board.

DIAGNOSTIC CODES LEDS