EXPANSION BOARD OVERVIEW

ADDITIONAL FEATURES

EXPANSION BOARD OVERVIEW

CYCLE COUNT

* First, note the current Aux Relay switch positions. To

determine the actual cycles that the gate operator has

run (in thousands), set all three Aux Relay switches to

the ON setting for Aux Relay 1. The Expansion Board’s

OPEN, CLOSE, and STOP LEDs will blink out the cycle

count, with OPEN LED blinking 1000’s, CLOSE LED blink

10,000’s, STOP LED blinking 100,000’s, and

simultaneously all three LED’s blink 1,000,000’s (e.g.

Open blinks 3 times, Close blinks 6 times, and Stop

blinks once. Cycle count is 163,000.). Cycle count

displayed is between 1,000 and 9,999,000 cycles.

After servicing, set Aux Relay switches back to their

appropriate positions. Cycle count cannot be reset or

changed. If under 1,000 cycles the Open, Close, and

Stop LEDs will turn on for 10 seconds, then turn off.

QUICK CLOSE Switch

OFF: No change to the gate's normal operation.

ON: When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the Timer-to-Close).

AC FAIL OPEN/BATT

Switch

OPEN: Loss of AC power will cause gate to immediately OPEN and remain OPEN until AC power is restored (enabling the Timer-to-Close).

BATT: With loss of AC power, gate will remain in present position and operator is powered from batteries.

LOW BATT/EXIT LOOP

FAIL Switch

• When AC power is OFF and battery voltage is low the gate will latch at a limit until AC power is restored or batteries voltage increases.

• Option select switch set to OPEN forces gate to latch at the OPEN limit if it is at the OPEN limit or on next open command until AC power is restored or

battery voltage increases.

• Option select switch set to CLOSE forces gate to latch at CLOSE limit if at CLOSE limit or on next CLOSE command until AC power restored or battery

voltage increases.

• Constant pressure on a hard command input overrides to open or close the gate.

• Low battery detect point = 22 V

• When set to OPEN, if the EXIT plug-in loop detector detects a fault, then the gate will open and remain open until fault is cleared. When set to CLOSE,

then plug-in EXIT loop detector faults are ignored (EXIT loop is faulted and inoperative).

ANTI-TAIL OPEN/CLOSE

SELECTION switch

OFF: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to stop and reverse.

ON: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to pause. Once the vehicle is clear the gate will continue to close.

AUX RELAY switches

Set the AUX RELAY switches as needed to obtain the desired function:

AUX RELAY

SETTING

SWITCH

SETTINGS

AUX RELAY 1

AUX RELAY 2

1

2

3

Off (no feature

selected)

OFF OFF OFF

Relay always off. Use this Aux Relay setting to conserve

battery power.

Relay always off. Use this Aux Relay setting to conserve battery power.

Open Limit

Switch

OFF OFF ON

Energizes at open limit. Use with SAMS (Sequenced Access Management

System, jointly with barrier gate)

Energizes when at open limit. Use with SAMS (Sequenced Access

Management System, jointly with barrier gate)

Close Limit

Switch

OFF ON OFF

Energizes when not at close limit. Connect “Gate Close/Secure” indicator

(e.g. light).

Energizes when not at close limit. Connect “Gate Not Closed/Secure”

indicator (e.g. light).

Gate Motion OFF ON ON

Energizes when motor is on (gate in motion). Connect “Gate In Motion”

indicator (e.g. warning light or sounder).

Energizes when motor is on (gate in motion). Connect “Gate In Motion”

indicator (e.g. warning light or sounder).

Pre-Motion

Delay

ON OFF OFF Energizes 3 seconds before gate motion and remains energized during gate

motion. Connect “Gate In Motion” indicator (e.g. warning light or sounder).

Not used.

Power

ON ON OFF Energizes when AC power or solar power is present. There is approximately

a 10-12 second delay before relay cutoff, after AC shutdown.

Energizes when on battery power. There is approximately a 10-12

second delay before relay cutoff, after AC shutdown.

Tamper

ON OFF ON

Energizes if gate is manually tampered with by being pushed off of close

limit. Connect alert (e.g. light or sounder).

Energizes if gate is manually tampered with by being pushed off of close

limit. Connect alert (e.g. light or sounder).

Cycle Quantity

Feedback*

ON ON ON

The OPEN, CLOSE, and STOP LEDs will blink out the cycle count

See below.

Not used.

To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.