9 © Adam Equipment Company 2011

Figure 1A shows the connections to a 6 wire load cell. Figure 1B shows a preferred

method to attach a 4 wire load cell, using a 6 conductor cable to go from the

indicator to the platform or load cell where it connects to the 4 wires from the load

cells. The Excitation and sense wires are connected together near the load cell.

For less exacting applications you can connect the excitation to the sense at the

connector.

KEYPAD

KEYS

PRIMARY FUNCTION

SECONDARY FUNCTION

[Zero]

Sets the zero point for all subsequent

weighing. The display shows zero.

Escape from any setting menus

[Tare]

It tares the indicator and stores the current

weight in memory as a tare value, subtracts

the tare value from the weight and shows

the results. This is the net weight.

Accept the set values

[Unit]

This is used to select the weighing units

from a preset list of available units.

Allows the weight, unit weight, and

count to be seen when parts

counting or to change from weight

to % in percent weighing

Advertising