FEC DSP1500 (SAN3) User Manual

Page 11

Advertising
background image

enFORCE

SAN Unit Operation Manual

PAGE 6 - 11

Chapter 6: System Operation

6.3.5 Press Result Display Mode

The following is displayed on the screen in the Press Result Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.

D-NO DATA UNIT

_0

Peak Load Value(Judgment Load Value) KN

_1

Final Distance Value

mm

_2

(Not Used) 1

st

Load Rate Value

KN/mm

_3

(Not Used) 2

nd

Load Rate Value

KN/mm

_4

1

st

Region Operating Time

Sec

_5

Final Region Operating Time

Sec

_6

Cycle Time

Sec

_7

Operation Mode Number

_8

Thermal value at Operation End (abnormal occurs if greater than 100)

_9

Lower 4 digits of final distance value (v1.96 or later)

-0

Press Method Number

-1

Step

-2

Distance when Press Speed Load was Detected (v1.96 or later)

mm

-3

Self Check ON: performed OFF: not performed

-4

Speed when Speed Change Load was Detected (v1.96 or later)

mm/sec

-5

Cause of press stop

0: Reset/No Data/After manual operation 1: Abnormal
2: BYPASS signal 3: STOP signal 4: REJECT
5: ACCEPT signal 6: START signal OFF * 7: CW signal *
8: CCW signal * *(v1.96 or later)

-6

Load Judgment Ld (Blank=Accept, H=High Reject, L=Low Reject)

-7

Distance Judgment dS (Blank=Accept, H=High Reject, L=Low Reject)

-8

Load Rate Judgment rt (Blank=Acc., H=High Rej., L=Low Rej., Z=1

st

Zone)

-9

Time Judgment Γi (1

ST

, 2

ND

(Blank=Accept, H=High Reject)

=0

(Not Used) 1

ST

Load Rate Area Increment Load

KN

=1

(Not Used) 2

ND

Load Rate Area Increment Load

KN

=2

(Not Used) 1

ST

Final Load

KN

=3

(Not Used) 1

ST

Peak Load

KN

=4

Final Load Value

KN

=5

Distance at Peak Load (judgment load) mm


D-NO」 「DATA


Peak load value



Final Distance value



1ST Load Rate






Distance at Peak Load

D-NO

left side figure

[↑] / [↓]

buttons