enFORCE

SAN Unit Operation Manual

PAGE 6 - 45

Chapter 6: System Operation

6.5 Setting Up a Parameter for Returning

It is recommended that, if the return of the press is done with a parameter, use Distance Control.
However, if Target Distance is set to 0 without a return operation, the press will reject because the
Distance Low value is zero (a value less than zero is not possible).
Refer to the following for setting up a Return Parameter. Adjustments can be made according to
the individual application.

D-NO DATA

SETTING

00

Press

Operation

0001

(Distance Control+Return Operation)

11

Load Low Limit

0

12

Load High Limit

Maximum Load of the Tool

14

Press Speed Start Load

1 or Maximum Load of the Tool

15

Interference Check Load

Maximum Load of the Tool

16

Distance Measurement Start Load 0

17

Part Check Low

Maximum Load of the Tool

20

Distance Low Limit

0

21

Distance High Limit

2

22

Target

Distance

1

(setting to 0 will cause a reject)

23

Interference Check Distance

3

24

Press Speed Start Distance

2

30

Advance Position ON Distance

0

31

Advance Position OFF Distance

0

(if using Rates, set to maximum)

32

Return Position ON Distance

0

33

Return Position OFF Distance

0

(if using Rates, set to maximum)

40

Slow Start Time

0

41

1

St

Time High

120

42

2

nd

Time High

120

50

Slow Start Speed

1

51

Approach Speed

100

52

Part Search Speed

5

53

Press Speed

3

54

Return Speed

5

60

Approach

Distance

10

(may need to set larger for higher speeds)

61

Load Hold Time

0

62

Job Start Position

0

64

Distance

Offset

0