FEC DSP1500 (SAN3) User Manual

Page 28

Advertising
background image

enFORCE

SAN Unit Operation Manual

PAGE 6 - 28

Chapter 6: System Operation

Load Rise Detection (Method 2 – Type 2)

This Load Control press method allows judgment of a distance (DS) at a given load
[18: Detection Start Load] and press rate [33: Load Rate Change].
Type 2 Control is active if [22: Target Distance] is set to 0.
Upon start of cycle, the press will operate until it achieves [13: Target Load]. During
the press cycle, as soon as [18: Detection Start Load] is achieved, a rate calculation
will begin based upon the load seen at a distance of .1mm before the [18: Detection
Start Load]
distance and will continue to be calculated every .1mm until [33: Load
Rate Change]
is exceeded. During the press cycle, checks are performed
for ”Interference Check” / “Part Check”, Load and Distance. If any of these values are
compromised, the press will stop and return as programmed.

Final Judgment is based

on the distance where the rate exceeds [33: Load Rate Change] after [18: Detection
Start Load]
has been achieved

.

(See corresponding sections for Interference Check and Part Check explanations.)






ƒ

[33: Load Rate Change] is a “control” function and is not used for judgment.

ƒ

Timing Signal Output function cannot be used in conjunction with this method.

ƒ

If “Interference Check” or “Part Check” are not used, set [15: Interference Check

Load / Part Check Load High] and [17: Part Check Load Low] to [10: CAL
Load]
and [23: Interference Check Distance / Part Check Distance] to a
minimum of [21: Distance High Limit].

ƒ

Review Speed Section explanations and cautions when setting [15: Interference

Check Load / Part Check Load High], [14: Press Speed Start Load], [24: Press
Speed Start Distance]
and [20: Approach Distance].

Load

Distance

Max

Load Limit is set to

1.1 x [10] Calibration Load

[11] Load Low Limit

[13] Target Load

[15] Part Check Load High

(Interference Check Load)

[17] Part Check Load Low

[20]

Distance

Low Limit

[21]

Final
Distance Limit

[23]

Part Check Distance

(Interference Check Distance)

Part Check - High

(Interference Zone)

Final Judgment Zone

(DS)

Judgment

Distance

[18] Detection Start Load

[12] Load High Limit

[18] Detection Start Load

(

DS) - .1mm

(

DS) + .1mm

(DS)

[33] Load Rate Change

[24]
Distance

High Limit

Part Check - Low