Chapter 6: System Operation

Data Number Conversion Table

Item

Parameter

Number

PARM

Data

Number D-

No

DATA







System

00

00

Load

unit

number

:KN 1: Klbs. 2: Metric Ton

00

01

SP version/copy between parameter <No change>

00

02

Amplifier Version <No change>

00

03

Function Version <No change>

00

04

Off Set Load

00

05

Distance Compensation [mm]

00

06

No Load Current Limit 0~1023

00

07

Home Position Off Set [mm]

00

08

Home

Position

Sensor/PLC Bank Select

00

09

Home position search time out 0.1[sec] unit

00

0A

Distance Decimal / Deadman / Comm Speed / Timing Signal

00

0B

Approach

Distance

Limit/Load Cell Availability

00

0C

Current Load Conversion Ratio [%]

00

0D

Stroke Distance Limit/Load Hold Time Decimal Point

00

0E

MANUAL

Speed [mm/sec]

00

0F

Dynamic Hold / RS232C Output/Speed Decimal Point

Tool

Data

00

10

Tool

Number

00

11

Tool

CAL

Load

00

12

Tool CAL Voltage [V]

00

13

Tool Zero Load Voltage [V]

<No change>

00

14~1A

In House Control Data

Tool Type

00

20

Tool

Number

01~32

00

Press Mode (Press Method + Return Operation+ Judgment Operation)

Load

01~32

10

Full-Scale

Load

01~32

11

Load Low Limit

01~32

12

Load High Limit

01~32

13

Target

Load

01~32

14

Press Speed Start Load

01~32

15

Interference Check Load / Part Check Load High Limit

01~32

16

Distance Measurement Start Load

01~32

17

Part Check Load Low Limit

01~32

18

Detection Start Load/Time Start Load (2

nd

Rate Start Load)

Distance

01~32

20

Distance Low Limit [mm]

01~32

21

Distance High Limit [mm]

01~32

22

Target Distance [mm]

01~32

23

Interference Check Distance / Part Check Distance [mm]

01~32

24

Press Speed Start Distance [mm]

Special Option

01~32

30

Advance Position ON Distance (1

st

Rate Low) [mm]

01~32

31

Advance Position OFF Distance (1

st

Rate High) [mm]

01~32

32

Return Position ON Distance (2

nd

Rate Low) [mm]

01~32

33

Return Position OFF Distance (2

nd

Rate High) [mm]

Time

01~32

40

Slow Start Time [sec]

01~32

41

1

ST

Time High Limit [sec]

01~32

42

2

ND

Time High Limit / Press Time [sec]

Speed

01~32

50

Slow Start Speed [mm/sec]

01~32

51

Approach Speed [mm/sec]

01~32

52

Part Search Speed [mm/sec]

01~32

53

Press

Speed [mm/sec]

01~32

54

Return

Speed [mm/sec]

01~32

60

Approach Distance [mm]

Special Setting

01~32

61

Load

Hold

Time

[sec]

01~32

62

Job Start Position [mm]

01~32

63

Load

Change

01~32

64

Distance Off Set [mm]