Chapter 6: System Operation

Distance Control with Load Limit (Method 7)

Upon start of cycle, the press will operate until it achieves [22: Target Distance].
During the press cycle, after achieving [13: Target Load], the press rate will be current
controlled to hold [13: Target Load] until [22: Target Distance] is reached. During the
press cycle, checks are performed for “Interference Check” / “Part Check”, Load and
Distance. If any of these values are compromised, the press will stop and return as
programmed.
(See corresponding sections for Interference Check and Part Check explanations.)




ƒ

If “Interference Check” or “Part Check” are not used, set [15: Interference Check

Load / Part Check Load High] and [17: Part Check Load Low] to [10: CAL
Load]
and [23: Interference Check Distance / Part Check Distance] to a
minimum of [21: Distance High Limit].

ƒ

Review Speed Section explanations and cautions when setting [15: Interference

Check Load / Part Check Load High], [14: Press Speed Start Load], [24: Press
Speed Start Distance]
and [20: Approach Distance].











Load

Distance

[12] Load High Limit

[11] Load Low Limit

[13] Target Load

[15] Part Check Load High

(Interference Check Load)

[17] Part Check Load Low

[20]

Distance

Low Limit

[21]

Distance
High Limit

[23]

Part Check Distance

(Interference Check Distance)

Part Check - High

(Interference Zone)

Final Judgment Zone

[22]

Target

Distance

Part Check - Low