enFORCE

SAN Unit Operation Manual

PAGE 6 - 34

Chapter 6: System Operation


ƒ

Final Load Low Limit Judgment Disable [ 0 ]

Judgment of a “Low Load” condition at the end of the press cycle will not be reported.
All other judgments will be reported.

ƒ

Final Load Low Limit Judgment Enable [ 1 ]

Judgment of a “Low Load” condition at the end of the press cycle will be reported.
All other judgments will be reported.

ƒ

Part Check + Final Load Low Judgment [ 3 ]

All programmed judgments will be performed. This selection also enables the “Part
Check” functionality.

At [23: Part check Distance], the judging of an abnormally high or low load is possible.
If a load value greater than [15: Part Check Load High] is sensed before the press
exceeds [23: Part Check Distance], a “1

ST

Zone High” reject will occur and press

operation will stop.
Upon reaching [23: Part Check Distance], if [17: Part Check Load Low] has not
been reached, a “1

ST

Zone Low” reject will occur and press operation will stop.





















Judgment Operation

Part Check - Low Load Zone

(Under Tolerance or No Part)

Part Check - High Load Zone

(Over Tolerance or Obstruction)

Load

[15] Part Check

Load High

[23] Part Check Distance

[17] Part Check

Load Low

Distance

Part Check