6.4 BYPASS Mode Operating Instruction

When the RUN/BYPASS switch is moved to the BYPASS position or when a Bypass signal is
received from a PLC the BYPASS led will blink and the unit will be in the BYPASS state. In this state,
the Press Unit number (U.01 to 32) is displayed on the screen.







6.4.1 Download Mode and Setup Mode Selection

“Download Mode”

Immediately after the Bypass condition has been entered, the unit is in the Download Mode,
which allows the system to be set up using the DSP User Console software via the RS-485 port.
The DSP software allows SAN Unit setup via a computer versus programming with the Display
Panel. It is highly recommended that, with multiple numbers of

enFORCE

Units, the DSP

software be used because all presses can be programmed and downloaded to at the same time.
L.485 is displayed on the screen when downloading or uploading data.







To program the SAN Unit with the Display Panel, press the [MODE] button to change from
“Download Mode” to “Setup Mode”.

When the SAN Unit is performing a data transfer with an external computer,
changes cannot be made until the operation has been completed.


“Setup Mode”

Immediately after entering into the Setup Mode, a cursor (blinking for data entry) appears on the
“PARM” display. Each time the [MODE] button is pressed, the cursor (blinking character) will
shift to the right.
By pressing the [↑] and [↓] buttons, the value of the blinking character will increase or decrease.
The data corresponding to the selected parameter number “PARM” and data number “D-NO” is
shown in the “DATA” display.
You may edit the currently indicated data using the Data Edit Mode. Press the [SET] button to
enter into the Data Edit Mode for the indicated “D-NO” you want to change.