enFORCE

SAN Unit Operation Manual

PAGE 6 - 25

Chapter 6: System Operation

Load Control (Method 0)

Upon start of cycle, the press will operate until it achieves [13: Target Load]. During
the press cycle, checks are performed for “Interference Check” / “Part Check”, Load
and Distance. If any of these values are compromised, the press will stop and return as
programmed.

(See corresponding sections for Interference Check and Part Check explanations.)



ƒ

If “Interference Check” or “Part Check” are not used, set [15: Interference Check

Load / Part Check Load High] and [17: Part Check Load Low] to [10: CAL
Load]
and [23: Interference Check Distance / Part Check Distance] to a
minimum of [21: Distance High Limit].

ƒ

Review Speed Section explanations and cautions when setting [15: Interference

Check Load / Part Check Load High], [14: Press Speed Start Load], [24: Press
Speed Start Distance]
and [20: Approach Distance].










Load

Distance

[12]

Load High Limit

[13] Target Load

[11] Load Low Limit

[15] Part Check Load High

(Interference Check Load)

[17] Part Check Load Low

[20]

Distance

Low Limit

[21]
Distance

High Limit

Part Check - High

(Interference Zone)

Final Judgment Zone

[23]

Part Check Distance

(Interference Check Distance)

Press Methods

Part Check - Low