enFORCE

SAN Unit Operation Manual

PAGE 6 - 4

Chapter 6: System Operation

6.1.2 RS-232C Output Data

Result data is output every time the operation is finished.
The result output is possible for each unit that has a SAN –DP2S/SP4S installed.
Use SAN –IF unit if you want to output multiple results.

Result Output Data

Data Length: 78 bytes fixed (78 letters)

Normal data format

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

COUNT Number

Press

Number

PARM

Number

30H 30H 30H 31H 20H 20H 20H 20H 30H 31H 20H 20H 20H 31H 20H 20H

0 0 0 1 0 1 1

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

PEAK LOAD

Judg
ment

FINAL DISTANCE

Judg
ment

31H 32H 2EH 33H 34H 20H 20H 20H 31H 32H 2EH 33H 34H 20H 20H 20H

1 2 . 3 4 1 2 . 3 4

33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

FINAL LOAD

1ST RATE

Judg
ment

31H 32H 2EH 33H 34H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H 20H

1 2 . 3 4 0 . 1 2 3

49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64

2ND RATE

Judg
ment

1ST TIME

Judg
ment

30H 2EH 31H 32H 33H 20H 20H 20H 20H 31H 30H 2EH 30H 20H 20H 20H

0 . 1 2 3 1 0 . 0

65 66 67 68 69 70 71 72 73 74 75 76 77 78

2ND TIME

Judg
ment

Judg

ment

CR

LF

20H 20H 32H 2EH 30H 20H 20H 20H 4FH 20H 20H 20H 0DH 0AH

2 . 0 O

Overall Judgment
"O":4FH ACCEPT
"X":58H REJECT

"0001 01 1 12.34 12.34 12.34 0.123 0.123 10.0 2.0 O" +CR+LF

Judgment letters displayed Judgment letters displayed Judgment letters displayed
beside PEAK LOAD value: beside FINAL DISTANCE value: beside 1

ST

& 2

ND

RATE value:

“ ” (20H): ACCEPT

“ “ (20H): ACCEPT

“ “ (20H): ACCEPT

“H” (48H): Above High Value

“H” (48H): Above High Value

“H” (48H): Above High Value

“L” (4CH): Below Low Value

“L” (4CH): Below Low Value

“L” (4CH): Below Low Value

“A”

(41H):

Abnormal

Judgment letters displayed

“S” (53H): STOP

beside 1

ST

RATE value:

“B”

(42H):

BYPASS

“Z”

(5AH):

1

ST

Zone Reject


Judgment letter displayed beside TIME value:

“ “ (20H): ACCEPT

“H” (48H): Above High Value


COUNT Number: ‘0001’ is displayed after powering ON. 1 is added after each cycle.