Mma-303 direct/indirect charge - introduction, Specifications (continued) – Ransburg MMA-303 Direct_Ind Charge Atomizer A12870 User Manual
Page 14

MMA-303 Direct/Indirect Charge - Introduction
11
LN-9269-11.3
Mechanical (Continued)
Maximum Fluid Pressure Supply
Paint:
200 psi (1379 kPa)
Solvent:
150 psi (1035 kPa)
Fluid Flow Rate:
25-700 cc/min. (Maximum 300 cc/min. on 30mm Bell Cup)
Bell Cup Cleaning Time
(Internal/External):
2.7 sec. (approx.)
Color Change Time:
Dependent on system configuration, fluid pressures, fluid vis-
cosity, fluid line lengths, etc.
Speed Readout:
Magnetic pick-up, unidirectional fiber optic transmission
Bell Cup Replacement Time:
Less than 2 min.
Minimum Control Equipment
Requirements:
(Versions listed or higher)
MicroPak
LECU5004-11 (V.3.84)
Atomizer Module
A11925-00 (V.0.4)
I/O Module
A11435-00 (V1.4) (0.01V) (4-20 mA)
* Specifications and ratings based on testing at sea level standard conditions.