Mma-303 direct/indirect charge - maintenance – Ransburg MMA-303 Direct_Ind Charge Atomizer A12870 User Manual

Page 86

Advertising
background image

MMA-303 Direct/Indirect Charge - Maintenance

83

LN-9269-11.3

DISASSEMBLY PROCEDURES
(Cont.)

Replacement

Apply a light coating of O-ring lubricant to all
the O-rings and the threads of the turbine and
turbine retaining ring prior to assembly. Push
the turbine down into the cavity in the atomizer
body. Align the mark on the turbine with the
mark on the atomizer body. Install the turbine
retaining ring and o-ring by hand. Use the
spanner wrench to tighten an additional 1/8-
1/4 turn. (Lightly lubricate O-ring with petrole-
um jelly.) Check centering of fluid tube. If fluid
tube is centered, the turbine is fully seated. If
not, check tightness with spanner wrench. If
tube is not centered, again remove turbine and
check for causes, such as an O-ring fell off,
fiber optic not fully installed, foreign material
on seating surface, etc. Reinstall and recheck
tube centering.

Fluid Tip Removal / Replacement

Removal

To remove the fluid tips, use the tip/tube re-
moval tool (A11229-00). Insert the tool over
the tip and engage the four (4) prongs of the
tool into the four (4) slots in the tips (see “Fluid
Tip Removal” figure).

A11229-00
TOOL

FLUID

TIP

ENGAGE

PRONGS INTO

SLOTS

Fluid Tip Removal

To remove, turn the tip CLOCKWISE. The
thread on the tip is left hand.

N O T E

Fluid Tip

The fluid tip may be removed either with the
turbine in place, or the turbine off the unit.
“Fluid Tip Removal” figure shows removing the
tip with the turbine in place.

This allows removal and replacement of the
fluid tip while the applicator is on line.

Fluid Tip Removal