MMA-303 Direct/Indirect Charge - Maintenance

LN-9269-11.3

70

MMA-303 PREVENTIVE MAINTENANCE SCHEDULE

Frequency (Maximum)

Procedure

Mid-Shift End of Shift

Weekly

2

Weeks Monthly 3 Months 6 Months

Yearly

Mid Shift Cleaning

X

• Wipe electrodes

• Wipe shroud

• Visually inspect cup

End of Shift Cleaning

X

• Wipe electrodes

• Wipe shroud

• Wipe bell cup down

• Change cloth cover

Shaping Air Shroud

X

X

X

• Clean inner shape air ring

• Clean outer shape air ring

• Remove and clean

Bell cup removal/
inspection/

X

X

cleaning

Fluid Tip inspection/
cleaning

X

X

Inspect Valve and Seat

X

Assembly in Valve Module

for leaking

Replace Valves and Seats

X

in Valve Module

High Voltage Cable

X

X

Inspections

High Voltage Testing

X

Regreasing of High Voltage

X

Cables

Check resistance of High

X

Voltage Electrodes

Regreasing Electrode

X

Cavities of High Voltage

Ring and High Voltage In-
put

Inspect all Screws

X

• Replace if broken

• Inspect for wear

• Tighten per specifications