MMA-303 Direct/Indirect Charge - Operation

LN-9269-11.3

60

Typical Paint Sequence

Typical Color Change Sequence

Sequence Event Explanation:

1. Bell to Speed - This is accomplished by a

set point command from either the PLC,
robot, or other input device, through the I/O
module.

2. Shaping Air - Set to 350-400 SCFM while

performing a cup flush.

3. Voltage On - The voltage is turned on

from a signal to the MicroPak. The lag
time to full voltage may be reduced if a set-
back voltage is used. Recommended set-
back voltage is between 30 kV and 50 kV.

4. Trigger Fluid - An air signal is sent

through the PT line of the tubing bundle.
This should occur when the target is 6-12-
inches (152.4-304.8mm) from the applica-
tor centerline. (Not to be confused with
target distance.)

5. Voltage Off/Setback Voltage - Immedi-

ately precedes the trigger off. Using a
setback voltage shortens the cascade
voltage ramp up time.

6. Fluid Trigger Off - This should occur

when the target is typically 0-6-inches (0-
152.4mm) past the applicator centerline.

7. Shaping Air to Setback - The setback

flow of air should never be below 70 slpm
(2.6 SCFM) for the inner shape air except
when performing a cup flush sequence..

8. Color Change Sequence - Used when

color is changed one to the other. Typical
sequence is shown in “Typical Color
Change Sequence” figure in the
“Operation” section. (Note: During this
sequence, the applicator should be
moved to a position to collect the
waste material.)

The sequence shown is

a starting point for processing, but the fi-
nal sequence will depend on the material
being sprayed and the solvent used to
purge the applicator with.